IGE-XAO is becoming ETAP - English UK
IGE-XAO is becoming ETAP - English UK
  • Видео 129
  • Просмотров 978 802
V8R4 New Features Filter Equipment from the Drawing
Pre-filter the equipment shown by using symbol attributes. This new feature allows one or more equipment attributes to be added to a symbol and predefined to act as filters for the equipment database search.
Просмотров: 1 312

Видео

V8R4 New Features Improved Image Handling
Просмотров 761Год назад
Holding Ctrl whilst resizing an image on the page now maintains the aspect ratio and right-clicking the picture shows an option to change the image to another without re-inserting.
V8R4 New Features Highlight Attributes
Просмотров 758Год назад
Using the right-Ctrl key to momentarily highlight the main attributes in the active page. This highlights attributes with different colours for products, function & location, equipment and cross referencing. Releasing the Ctrl key returns the screen to normal.
V8R4 New Features Polygon Function Location Areas
Просмотров 1,3 тыс.Год назад
Draw new function and location areas as polygons to group components in irregular shaped areas.
V8R4 New Features Equipment Verification
Просмотров 710Год назад
Verify that the channel definition in the equipment database is accurately defined.
V8R4 New Features Alternative Symbols
Просмотров 1,1 тыс.Год назад
Include additional symbols to the channel definitions in the equipment database for increased versatility.
V8R4 New Features Attribute Tabs and List Boxes
Просмотров 775Год назад
Use attribute tabs to organize workspace and page information and quickly add new attributes with dropdown menus for faster selection.
V8R4 New Features Signal Direction Switch
Просмотров 1 тыс.Год назад
Quick example and background information on how to switch signal reference direction arrows by holding Shift and double-clicking on the signal.
V8R1 IEC Tutorial
Просмотров 38 тыс.2 года назад
This tutorial provides a quick example of creating a simple See Electrical V8R1 IEC project. This shows creating 2 pages of schematic with wiring, symbols, referencing, cables, and numbering out of the box. www.ige-xao.com/images/en/pdf/products/see_electrical/SEE_Electrical_V8R1_IEC_Tutorial.pdf
Bold circles and dashed lines appear overnight in See Electrical
Просмотров 2,1 тыс.2 года назад
If your circuit diagrams suddenly appear with very bold circles and dashed lines in See Electrical and the View Line Width command seems reversed, then you're suffering from the effects of Windows Update KB 5006670. This started appearing on 12th October 2021 and at the moment can be resolved by uninstalling the update as shown in the video. This affects See Electrical V8R3 and V8R2. Be aware t...
Creating and Assigning Parts in See Electrical V8R3
Просмотров 8 тыс.3 года назад
Entering, creating and linking the type/part number information with See Electrical symbols. The video demonstrates what is possible on the Basic, Standard and Advanced levels together with the optional 3D Panel module and See Web Catalogue subscription.
PLC Main and Signal Creation in See Electrical V8R3
Просмотров 10 тыс.3 года назад
Showing the expected method for creating PLC Main symbols for referencing, power and coms together with the PLC Signals used for illustrating the wiring. Using these methods ensures that PLC data import/export works efficiently and the PLC reports can be utilised for documentation.
See Electrical V8R3 Component Symbol Creation
Просмотров 20 тыс.3 года назад
Demonstrates the simple process of creating component symbols, forced referencing, component with auxiliary contacts and components with cross reference symbols. See Electrical V8R3 SP3 is being used with the IEC European standard.
Sub Reports in 3D Panel Reporting
Просмотров 6443 года назад
How to add and link a sub report to your main See 3D Panel V2R2 reports. This provides a simple way to create a consistent report header with project details to be added to any report you design. 2 lines of script are required which require careful typing.
See Electrical 3D Panel - Webinar May 2021 - IGE+XAO UK
Просмотров 8 тыс.3 года назад
This is a recording of IGE XAO UK Webinar from 25th May 2021, demonstrating live creation of electrical circuits with wire numbering and parts and the assembly of the 3D panel together with automatic wire routing, shop floor module for wiring verification, creating new intelligent components from STEP files, and documenting the design back into the 2D environment. This webinar was conducted usi...
Creating Building Plan Electrical Symbols with Auto Rotation
Просмотров 1,6 тыс.3 года назад
Creating Building Plan Electrical Symbols with Auto Rotation
Symbol Display Group Controlling Attribute Visibility in See Electrical Building
Просмотров 1,1 тыс.3 года назад
Symbol Display Group Controlling Attribute Visibility in See Electrical Building
Why can't I assign or display a wire number?
Просмотров 4,3 тыс.3 года назад
Why can't I assign or display a wire number?
Renumber All Drawings in See Electrical V8R3 SP1
Просмотров 2,4 тыс.3 года назад
Renumber All Drawings in See Electrical V8R3 SP1
See Electrical V8R3 Enhanced Zoom Extents
Просмотров 1,6 тыс.3 года назад
See Electrical V8R3 Enhanced Zoom Extents
Advanced Control of Wire Number Text
Просмотров 4,9 тыс.3 года назад
Advanced Control of Wire Number Text
Define Signal Numbers by PLC Address
Просмотров 2 тыс.3 года назад
Define Signal Numbers by PLC Address
See 3D Panel - Step File to Intelligent Enclosure
Просмотров 1,6 тыс.3 года назад
See 3D Panel - Step File to Intelligent Enclosure
IGE XAO See Electrical 3D Panel+ Webinar April 2020
Просмотров 18 тыс.4 года назад
IGE XAO See Electrical 3D Panel Webinar April 2020
See Electrical with 3D Panel Demo
Просмотров 56 тыс.4 года назад
See Electrical with 3D Panel Demo
See Electrical Open Data Module handling PLC data
Просмотров 4,1 тыс.4 года назад
See Electrical Open Data Module handling PLC data
Understanding Block Planes in See Electrical 3D Panel
Просмотров 2,5 тыс.5 лет назад
Understanding Block Planes in See Electrical 3D Panel
See Electrical 3D Panel Scaling Inch Based Models
Просмотров 1,2 тыс.5 лет назад
See Electrical 3D Panel Scaling Inch Based Models
See Electrical 3D Panel Mating Snaps
Просмотров 2,1 тыс.5 лет назад
See Electrical 3D Panel Mating Snaps
Creating part numbers linked to 2D and 3D symbols in See Electrical 3D Panel+
Просмотров 2,9 тыс.5 лет назад
Creating part numbers linked to 2D and 3D symbols in See Electrical 3D Panel

Комментарии

  • @MarcosMalave-hb8vr
    @MarcosMalave-hb8vr Месяц назад

    hi, i have a problem using the option: "commands - colors- brep- change color on all faces" does export the correct color to the 3dpdf, however when looking for greater detail using the "commands - colors- brep- change color on single face" does not export the color assigned to the 3dpdf

    • @IGEXAOUK
      @IGEXAOUK 28 дней назад

      Yes you're right, currently these colors applied using this command are not displayed in the exported PDF, only the blocks original color is used. I've added this to the requested enhancements list.

  • @Marcosdj18
    @Marcosdj18 Месяц назад

    Hello, I have a question, because the symbols when exported from see electrical to 3DPDF lose or do not take the assigned color from the commands - color - brep option? When exporting them, they appear without color in the pdf file

    • @IGEXAOUK
      @IGEXAOUK 28 дней назад

      Yes you're right, currently these colors applied using this command are not displayed in the exported PDF, only the blocks original color is used. I've added this to the requested enhancements list.

    • @Marcosdj18
      @Marcosdj18 28 дней назад

      @@IGEXAOUK thanks for your answer

  • @Marcosdj18
    @Marcosdj18 Месяц назад

    Hello, I have a question, because the symbols when exported from see electrical to 3DPDF lose or do not take the assigned color from the commands - color - brep option? When exporting them, they appear without color in the pdf file

    • @IGEXAOUK
      @IGEXAOUK 29 дней назад

      Hi Marcos can you tell me which version of 3D Panel and which PDF viewer you're using and I'll check this out and get back to you.

    • @Marcosdj18
      @Marcosdj18 29 дней назад

      @@IGEXAOUK thanks for your answer, 3D panel designer version is V3R1 SP2 (3.12.21.5), I’m using acrobat reader DC, But the problem is not the pdf viewer.

    • @IGEXAOUK
      @IGEXAOUK 28 дней назад

      @@Marcosdj18 Yes you're right, currently these colors applied using this command are not displayed in the exported PDF, only the blocks original color is used. I've added this to the requested enhancements list.

    • @Marcosdj18
      @Marcosdj18 28 дней назад

      @@IGEXAOUK thanks for your answer

    • @Marcosdj18
      @Marcosdj18 28 дней назад

      @@IGEXAOUK thanks for your answer

  • @Marcosdj18
    @Marcosdj18 Месяц назад

    Hello, I have a question, because the symbols when exported from see electrical to 3DPDF lose or do not take the assigned color from the commands - color - brep option? When exporting them, they appear without color in the pdf file

    • @IGEXAOUK
      @IGEXAOUK 28 дней назад

      Yes you're right, currently these colors applied using this command are not displayed in the exported PDF, only the blocks original color is used. I've added this to the requested enhancements list.

    • @Marcosdj18
      @Marcosdj18 28 дней назад

      @@IGEXAOUK thanks for your answer

  • @Leo-wc3bc
    @Leo-wc3bc 2 месяца назад

    Hello, Will there be V8R4 tutorial ? I really enjoy watching your videos and im trying to learn SEE ELECTRICAL. Best regards

    • @IGEXAOUK
      @IGEXAOUK 2 месяца назад

      Thanks for the feedback, glad you're enjoying the videos. There aren't any plans to release additional full tutorial videos for now. The base functionality available in V8R1 still applies to V8R4, we've just added new features which are covered in the additional video snippets. If there's anything in particular you think isn't well documented, please tell us and we'll look at creating something to help.

    • @Leo-wc3bc
      @Leo-wc3bc Месяц назад

      ​@@IGEXAOUK Hello, I recently bought SEE electrical grow with web catalogue and i have a problem. After downloading symbols from the catalouge, they are nowhere to be found. Is there a quick fix or should I contact the customer help team. Best regards

    • @IGEXAOUK
      @IGEXAOUK Месяц назад

      @@Leo-wc3bc After downloading new parts you should be able to find these in the Components panel. The equipment should link to the appropriate symbol. To see the symbols you may need to right-click in space in the symbols panel and select the properties and enable the view of the @Manufacturer symbol database. These are the ones downloaded via the web catalogue.

  • @serggomon
    @serggomon 3 месяца назад

    Hello, I would like to ask you how is possible to make reference and comments/description for the PLC signal in one line, like 'Merge' in Components? For example: 'ChannelDescription =FF01\+S1\ 25.6 ' on the corresponding PLC main view?

    • @IGEXAOUK
      @IGEXAOUK 2 месяца назад

      Its a good idea so I'll submit this to the development team as an enhancement. At the moment its not possible to merge attributes together on a symbol.

  • @lrnmt2000
    @lrnmt2000 3 месяца назад

    Hi sir. Do you know how and where to download symbols library?

    • @IGEXAOUK
      @IGEXAOUK 3 месяца назад

      Hi @Irnmt2000 most equipment downloaded from the web catalog provide both circuit diagram and 3D Panel symbols. The web catalog is available through subscription from your local sales team. We do also have some additional 2D and manufacturer specific symbol databases for the circuit diagrams which we can send out on request. contact support-uk@ige-xao.com for more information.

  • @Kabukihkaka
    @Kabukihkaka 3 месяца назад

    Hi, I am using V8R3, spanish language versio, I cant find this command. Can you please write the exact command to use in the "enter command" text window? thank you

    • @IGEXAOUK
      @IGEXAOUK 3 месяца назад

      BlockConfigurator is the command for a blocked group on a page and DrawingConfigurator for the whole page configuration.

  • @ahmedaldrajee7705
    @ahmedaldrajee7705 5 месяцев назад

    Hello dear, when I access the program’s web catalog, it asks for a proxy number, where can I get it? Thank you

    • @IGEXAOUK
      @IGEXAOUK 5 месяцев назад

      This usually indicates that communication with the web server is not possible. Please check that you don't have a firewall blocking access to the web catalog. The address is in the settings of the equipment manager.

  • @josiasborges4069
    @josiasborges4069 5 месяцев назад

    Can I show All terminals connected in on component for example my plc card L+ is connected on X1:2, X1:3, X1:4 AND X1:5 for example.

    • @IGEXAOUK
      @IGEXAOUK 5 месяцев назад

      Most things are possible with a database containing the project information :) Just need to clarify if you need all terminals connected on a specific potential or all terminals connected to a specific symbol.

    • @josiasborges4069
      @josiasborges4069 4 месяца назад

      @@IGEXAOUKis on symbol, but I was thinking there was a especifiic option on assembly for do that, I wanted assembly do all the connections beteween components\symbols and terminals.

  • @uppalurisravanthi7277
    @uppalurisravanthi7277 5 месяцев назад

    Please give me a suggestions about it

  • @uppalurisravanthi7277
    @uppalurisravanthi7277 5 месяцев назад

    I tried to create new symbol but connections dots not displayed?

  • @uppalurisravanthi7277
    @uppalurisravanthi7277 5 месяцев назад

    Recently installed free 30 days software

  • @webprotector19
    @webprotector19 5 месяцев назад

    hello @IGEXAOUK, i have a question for you. When i generate Legend, some symbols won`t show on legend (ex. "Two way switch" & "intermediate switch"). Do you know what can be the problem?

    • @webprotector19
      @webprotector19 5 месяцев назад

      @@IGEXAOUK Thank you for the response. I was the second answer: 2) The symbol has not been added to the list in the command GenerateLegendMapping section. You are the best!

  • @josiasborges4069
    @josiasborges4069 6 месяцев назад

    you removed the "name" from atributes?

  • @user-dw6bo3gd9q
    @user-dw6bo3gd9q 6 месяцев назад

    Its does not work.... I cant change the direction...

    • @IGEXAOUK
      @IGEXAOUK 6 месяцев назад

      @@user-dw6bo3gd9q Thanks for the quick update. Yes if you copy the V8R3 system.ses file across to V8R4 then you'll miss out on the direction swapping for the signal references.

  • @josiasborges4069
    @josiasborges4069 6 месяцев назад

    I have a doubt, but it's not about the video. I have been using this software for a long time and have a lot of development and experience in the autogen module, but now since the terminals have become like components, when I generate the auto diagram they no longer increase the numbering according to the order of the terminal strip, it simply repeats the saved number. Is there any easy way to fix this (some config) or will I have to change all my drawings to # in the terminal numbers?

  • @josiasborges4069
    @josiasborges4069 8 месяцев назад

    In this version I can create a cross-referenced component where the first part is a component and the second part is a component not in list (except as target). In my example I don`t want combine all parts of my components for avoid duplicates on material list, so for the first part of my symbol is component and the anothers not, But I don`t got sucesfull unsing cross referencies.

    • @IGEXAOUK
      @IGEXAOUK 8 месяцев назад

      In newer versions of SEE Electrical, use the 'Contacts, not specified' symbol type for the auxiliary symbols and add cross reference attributes to these and the 'Component with Aux Contacts' symbol to show the page references. Each product used will have just one set of equipment for the material list.

  • @josiasborges4069
    @josiasborges4069 8 месяцев назад

    I want change the kind of text showed on 180010 in my example I want replace the text "Electric Diagram IEC" for "x" do you have any Idea ?

    • @IGEXAOUK
      @IGEXAOUK 8 месяцев назад

      If you have the advanced or scale level package then you can use the report generator to add a new calculated field to the field list such as; iif([180010]= 'Circuit Diagram IEC','x',[180010]) The conditional iif statement is not available directly in the Graphical Lists.

    • @josiasborges4069
      @josiasborges4069 8 месяцев назад

      @@IGEXAOUK Can you make a video explain How to, I have de Advanced mode?

    • @IGEXAOUK
      @IGEXAOUK 8 месяцев назад

      Check this video for adding a calculated field ruclips.net/video/szJtLkdZT_Q/видео.html

    • @josiasborges4069
      @josiasborges4069 8 месяцев назад

      @@IGEXAOUK Thanks for helping this will be a lot useful

  • @plavooki95
    @plavooki95 8 месяцев назад

    Hello, In the BOM list, is it possible to aggregate cable lengths only by cable type or by some other attribute? E.g. description 00? I have the problem that I have the same cable types, but they don't all have the same text in the attribute "description 00"... Is it possible for the program to sum the cables by two different attributes?

  • @plavooki95
    @plavooki95 9 месяцев назад

    Hello, thanks for the useful tips. Is there some control code that sums the lengths of cables of the same type? In the parts list or in the cable list, I want to add up e.g. length of all cables type Ölflex Classic 110 and conductor cross-section 3x1,5 mm2.

  • @plavooki95
    @plavooki95 9 месяцев назад

    Hello, my desire is that i want to show in the cable list the cable that has multiple lines of text in the wiring diagram. Is it possible to show this in one extended line in the cable list? Is it possible to make a command for multiline text? I tried the following command but it didn't work: #160030 &MultiLine [ ]

  • @user-qb3lu3qm3w
    @user-qb3lu3qm3w 10 месяцев назад

    Hi, is it possible to extract values from "View, BOM" and edit those values in report generator. Say that I want to extract AMP values for instance "C 16A 30mA", but I don't want the C (from C curve characteristic) and I don't want the "A 30mA" either, just the raw number. I know it is possible to do in excel, but it would be nice if it was possible in report generator directly. Also, is it possible to add different sources for the Report Designer, because I need values from "Editor, Components" as well, in my report. As I see it, I have to choose one source and I can't combine several sources.

  • @santoshsengunther6974
    @santoshsengunther6974 10 месяцев назад

    Hi, Could you please help me... Do you know how to measure the overall heat dissipation of the electronic components? Here the component is ADAS front camera situated on car behind the windshield? Having processor, image sensor or other electronic components

    • @IGEXAOUK
      @IGEXAOUK 10 месяцев назад

      I'm sorry but our heat dissipation calculation is specifically tailored for electrical components contained within a panel, where the panel is either placed against a wall or next to another panel, which won't help with electronic components in a car.

  • @samuelkctweneboah-kodua5660
    @samuelkctweneboah-kodua5660 11 месяцев назад

    The best way to find a lot of people becoming used to this best light weight software is to introduce students version . the more we practice and familiar we recommend to industries to use as soon as we are employed . As software developer myself i understand what goes into it so making it free for students is difficult but i think numbers with time.

  • @samuelkctweneboah-kodua5660
    @samuelkctweneboah-kodua5660 11 месяцев назад

    GREAT

  • @KYSFaggo
    @KYSFaggo 11 месяцев назад

    What do I do when I try to create a new project, but don't see any templates after typing in my project name ?

  • @user-ep4qb8ci5s
    @user-ep4qb8ci5s Год назад

    Hi , When I open the see electrical selector I just see (system & template)

    • @IGEXAOUK
      @IGEXAOUK Год назад

      If this is See Electrical V8R4 then make sure to install a suitable IEC or NFPA environment. You can find the downloads here: ige-xao-uk.com/downloads/

  • @Xenomorphin1
    @Xenomorphin1 Год назад

    Does the software have a perpetual fallback license, or is it subscription only? I'd be willing to buy it, but we don't do electrical panels too often, since we're mostly a medical company.

    • @IGEXAOUK
      @IGEXAOUK Год назад

      Could you please tell me your country of residence? Then we will get the right contact person for you to answer your question. Thank you!

    • @Xenomorphin1
      @Xenomorphin1 Год назад

      @@IGEXAOUK It's Poland. I had someone call this morning, I'll call them back and ask.

  • @qzorn4440
    @qzorn4440 Год назад

    I am looking for an electrical CAD that has features like SolidWorks with a hobby price. This hobby project requires linking the PLC schematic with 3D sensors, 3D wringing harness. The Cad video looks very interesting. What is the software cost? Thanks.

  • @medaminekalboussi930
    @medaminekalboussi930 Год назад

    thank u so much really helpful i hope u still making educational vids about see electrical right now

  • @emran.hexecutive6317
    @emran.hexecutive6317 Год назад

    sir....pls give me ,,,,see electrical v8r2 software i can get it from any link urgent helpe me pls....

  • @DiwakarShankar-rz7jx
    @DiwakarShankar-rz7jx Год назад

    in see electrical, stretch command is not available? and also, what is the shortcut key for copy with reference point. i request to make a series of videos regarding commands only.

    • @IGEXAOUK
      @IGEXAOUK Год назад

      Graphical stretch can be enabled using the trackers (Alt+T), and stretch of connected wires using the Electrical - Wire Rubberband command. Right-click to select Copy with Base Point or add a new keyboard shortcut by right-clicking on the menu, accessing the quick access tool bar settings and clicking through to the keyboard shortcuts. I hope this helps.

  • @oseiasalencarjunior5145
    @oseiasalencarjunior5145 Год назад

    Great Job!

    • @IGEXAOUK
      @IGEXAOUK Год назад

      Thanks for the feedback Oseias.

  • @R1zla212
    @R1zla212 Год назад

    HOW TO SET A BASE POINT FOR PICK AND PLACE

    • @R1zla212
      @R1zla212 Год назад

      @@IGEXAOUK THANKS! IT HELPED

  • @dineshbabu6596
    @dineshbabu6596 Год назад

    Software link &product key plz

    • @IGEXAOUK
      @IGEXAOUK Год назад

      Hi Dinesh, you can download the software as a free 30 day trial from our Web site, either www.ige-xao.com or ige-xao-uk.com

  • @dineshbabu6596
    @dineshbabu6596 Год назад

    See electrical license installation video &license key

  • @dineshbabu6596
    @dineshbabu6596 Год назад

    India sales team phone number

    • @IGEXAOUK
      @IGEXAOUK Год назад

      Please contact Mohnish and his team #1/1, Gover Road Cox town Bangalore-560005 Phone : +91 9535235447

  • @patrikhercut6197
    @patrikhercut6197 Год назад

    Hello, I would like to ask you how is possible to create a single-line cable from multiple wires. Let's say 3 wires from the terminal creates a 3 cores cable. I saw the function multicore but I am not sure how is possible to work with this. Can you give me some ideas? Thank you!

  • @Schmorrison
    @Schmorrison Год назад

    Is V8R4 only available for the NFPA version? I use IEC normally but only see upto V8R3 SP6

  • @edimarneves5504
    @edimarneves5504 Год назад

    Olá tem versão em português Brasil ou Portugal?

  • @gerardbrouwer2581
    @gerardbrouwer2581 Год назад

    so i have some small problems. @4:44 i can't change the PLC adress numbering method, it doesn't allow me to make the change. and i think that is why @8:30 the numbering doesn't work automaticly work and @8:53 i cant select the PLC adress.

    • @IGEXAOUK
      @IGEXAOUK Год назад

      Auto numbering for the PLC is limited to the standard and advanced level packages, could it be that you're working with the basic level? A neat workaround is to open a spreadsheet to quickly generate a sequence of addresses, copy (Ctrl+C), then paste (Ctrl+V) the 4/8/16/32 addresses while the first address is selected in the Component Properties dialog for the PLC Main.

  • @Schmorrison
    @Schmorrison Год назад

    Been using the program for about a year, this is definitely a feature I've been hoping for. Keep up the videos!!

    • @IGEXAOUK
      @IGEXAOUK Год назад

      Thanks for the feedback. Don't forget, most new features come from user requests so keep pushing the product.

  • @soufelec6216
    @soufelec6216 Год назад

    Hello, I am a student. How can I get an app for free?

  • @erseayd
    @erseayd Год назад

    sir, when I enter the symbols section on my 3d panel drawing screen, no objects and materials are visible. It is empty, what is the reason please explain

  • @apvivek5368
    @apvivek5368 Год назад

    Can we design MV panels like with 15to20 ACB outgoing feeders? And have one more quiz,! Can we use this 3d model to for machining like laster sheetmetal laser cuttings?

  • @RaviShankar-lm3xn
    @RaviShankar-lm3xn Год назад

    Nice videos Sir and very helpful 🙏

    • @IGEXAOUK
      @IGEXAOUK Год назад

      Many thanks for the feedback. We're glad you found it useful. Creating PLC devices to make the most of See Electricals functionality takes a bit more consideration than most other symbols.

  • @nexttube7998
    @nexttube7998 Год назад

    Hi sir how i can change background page colour

    • @IGEXAOUK
      @IGEXAOUK Год назад

      Hi NEXTTUBE, close any projects and select File - System Settings and you should see a colours tab where you can change background and grid colours.